h2oguy | Aqua Specialties LLC :: Franklin Electric Single Phase Submersible Motor Specifications

 Search

 

Share |

Need help now? Call us at 1-800-729-0388

Follow us on twitter

Find us on Facebook

Home > Pumps & Wells > Well Pumps > Franklin Electric Single Phase Submersible Motor Specifications

Franklin Electric Submersible Pump Motors

Single-Phase Motor Specifications (60 Hz) 3450 RPM

We offer this advice assuming that you have the working knowledge of the tools necessary to safely perform these tests.

http://www.franklin-electric.com/aim-manual/page-13.aspx

 

Type Motor
Model Prefix
Rating Full Load Maximum Load Winding (1)
Res. In Ohms
Efficiency % Power
Factor %
Locked
Rotor

AMPS
KVA

Code
HP KW Volts Hz S.F. (2)
Amps
Watts (2)
Amps
Watts M=Main Res. S=Start Res. S.F. F.L. S.F. F.L.
244504 1/2 .37 115 60 1.6 10.0 670 12.0 960 1.0-1.3 62 56 73 58 64.4 R
244505 1/2 .37 230 60 1.6 5.0 670 6.0 960 4.2-5.2 62 56 73 58 32.2 R
244507 3/4 .55 230 60 1.5 6.8 940 8.0 1310 3.0-3.6 64 59 74 62 40.7 N
244508 1 .75 230 60 1.4 8.2 1210 9.8 1600 2.2-2.7 65 62 74 63 48.7 N
244309 1.5 1.1 230 60 1.3 10.6 1770 13.1 2280 1.5-2.1 64 63 83 76 66.2 M
214504 1/2 .37 115 60 1.6 Y10.0 670 Y12.0 960 M1.0-1.3
S4.1-5.1
62 56 73 58 50.5 M
B10.0 B12.0
R0 R0
214505 1/2 .37 230 60 1.6 Y5.0 670 Y6.0 960 M4.2-5.2
S16.7-20.5
62 56 73 58 23 M
B5.0 B6.0
R0 R0
214507 3/4 .55 230 60 1.5 Y6.8 940 Y8.0 1310 M3.0-3.6
S10.7-13.1
64 59 74 62 34.2 M
B6.8 B8.0
R0 R0
214508 1 .75 230 60 1.4 Y8.2 1210 Y9.8 1600 M2.2-2.7
S9.9-12.1
65 62 74 63 41.8 L
B8.2 B9.8
R0 R0
214504 1/2 .37 230 60 1.6 Y3.6 655 Y4.3 890 M4.2-5.2
S16.7-20.5
67 57 90 81 23 M
B3.7 B4.0
R2.0 R2.0
214507 3/4 .55 230 60 1.5 Y4.9 925 Y5.7 1220 M3.0-3.6
S10.7-13.1
69 60 92 84 34.2 M
B5.0 B5.2
R3.2 R3.1
214508 1 .75 230 60 1.4 Y6.0 1160 Y7.1 1490 M2.2-2.7
S9.9-12.1
70 64 92 86 41.8 L
B5.7 B6.2
R3.4 R3.3
214508
W/ 1 1/2
CB
1 .75 230 60 1.4 Y6.6 1130 Y8.0 1500 M2.2-2.7
S9.9-12.1
70 66 82 72 43 L
B6.6 B7.9
R1.3 R1.3
224300 1 1/2 1.1 230 60 1.3 Y10.0 1620 Y11.5 2080 M1.7-2.1
S7.5-9.2
70 69 85 79 51.4 J
B9.9 B11.0
R1.3 R1.3
224301 2 1.5 230 60 1.25 Y10.0 2025 Y13.2 2585 M1.8-2.3
S5.5-7.2
73 74 95 94 53.1 G
B9.3 B11.9
R2.6 R2.6
224302
(3)
3 2.2 230 60 1.15 Y14.0 3000 Y17.0 3400 M1.1-1.4
S4.0-4.8
75 75 99 99 83.4 H
B11.2 B12.6
R6.1 R6.0
224303
(4)
5 3.7 230 60 1.15 Y23.0 4830 Y27.5 5500 M.71-.87
S1.8-2.2
78 77 100 100 129 G
B15.9 B19.1
R11.0 R10.8
226110
(5)
5 3.7 230 60 1.15 Y23.0 4910 Y27.5 5570 M.55-.68
S1.3-1.7
77 76 100 99 99 E
B14.3 B17.4
R10.8 R10.5
226111 7 1/2 5.5 230 60 1.15 Y36.5 7300 Y42.1 8800 M.36-.50
S.88-1.1
73 74 91 90 165 F
B34.4 B40.5
R5.5 R5.4
226112 10 7.5 230 60 1.15 Y44.0 9800 Y51.0 11300 M.27-.33
S.80-.99
76 77 96 96 204 E
B39.5 B47.5
R9.3 R8.9
226113 15 11 230 60 1.15 Y62.0 13900 Y75.0 16200 M.17-.22
S.68-.93
79 80 97 98 303 E
B52.0 B62.5
R17.5 R16.9
 
(1)
Main winding - yellow to black
Start winding - yellow to red


(2)
Y = Yellow lead - line amps
B = Black lead - main winding amps
R = Red lead - start or auxiliary winding amps
   
(3)
Control Boxes date coded 02C and older have 35 MFD run capacitors and the current values will be
Y14.0 @ FL and 
Y17.0 @ Max Load.
B12.2
B14.5
R4.7
R4.5
 
(4)
Control Boxes date coded 01M and older have 60 MFD run capacitors and the current values on a 4" motor will be
Y23.0 @ FL -
Y27.5 @ Max Load.
B19.1
B23.2
R8.0
R7.8
   
(5)
Control Boxes date coded 01M and older have 60 MFD run capacitors and the current values on a 6" motor will be
Y23.0 @ FL -
Y27.5 @ Max Load.
B18.2
B23.2
R8.0
R7.8

Performance is typical, not guaranteed, at specified voltages and specified capacitor values. Performance at voltage ratings not shown is similar, except amps vary inversely with voltage.

AQUA SPECIALTIES LLC h2oguy.com
561 First NH Tpke || Northwood NH 03261
(603) 942-5671